1. Purpose of Calibration Using Cylindrical Pins#
We realized that the previous calibration methods for 3D printing had many deficiencies, such as factors like the accuracy and stiffness of 3D printed parts, as well as the time required to print calibration parts. Therefore, we proposed a standard part calibration scheme that uses cylindrical pins (GB119) to constrain the rotational degrees of freedom of each joint. This scheme aims to provide users with an alternative mechanical calibration method with high repeatability to achieve attitude constraint and zero alignment of each joint of the robot during the calibration process.
II. Potential issues in cylindrical pin calibration#
It should be noted that this type of calibration method has relatively high requirements for the manufacturing tolerances of components, including but not limited to dimensional errors, positional errors, and shape errors. Due to the process differences between different machining suppliers and different machining batches, even when the nominal dimensions are consistent, the actual fitting effects of parts may vary. Therefore, during actual use, it may occur that the cylindrical locating pin cannot be smoothly inserted, or although it can be inserted, it cannot be fully inserted to the designed depth, thus affecting its effectiveness in restricting the rotational degrees of freedom of the joint.
If the locating pin cannot be inserted manually, you can choose to use a rubber hammer or other tools to insert it.
In some cases, inserting the cylindrical pin to a certain depth can effectively constrain the rotation of the joint. After inserting the positioning pin, if the rotation of the relevant joint is found to have its rotational degrees of freedom restricted, it can be considered that the calibration and positioning have been completed, and there is no need to force it to the theoretical limit position. The BOM provides positioning pins of two lengths, 18 and 22. Due to interference at some positions, the user can choose cylindrical pins of different lengths.
If the plug is found difficult to pull out manually, tools such as needle-nose pliers can be used.
III. Installation Location Instructions#
The insertion positions of the locating pins for the arms and legs are shown in the figure (taking the right hand and right leg as an example). It should be noted that the illustrated solution imposes a certain degree of over-constraint on the rotational degrees of freedom of the legs. From a theoretical analysis perspective, only one locating pin needs to be inserted into the leg joint to achieve posture positioning. However, in actual engineering implementation, a multi-point constraint design solution is adopted to improve the stability and reliability of the calibration process.
**The limit and positioning of the lumbar joint ** are achieved jointly by ** the limit blocks on the "lumbar support structure" and the "battery bottom cover" **. If the assembly position is correct, the upper body will come into contact with the limit structure when rotating approximately ±120° in the clockwise or counterclockwise direction, thereby achieving the angular positioning of the lumbar joint.
Due to the existence of a certain angle between the rotation axis of the hip joint motor and the vertical direction, it is difficult to achieve stable and reliable posture positioning through a simple limit block structure. When the joint rotates to the limit position, the component force of gravity will drive the joint to return to its initial posture, causing the limit effect to fail. Therefore, no rigid limit blocks or positioning pin holes are provided for the rotational degrees of freedom of the two hip joints.
In the current solution, the calibration of the above joints still relies on a dedicated 3D printed calibration fixture to achieve pose constraint.
Theoretically, using a single 3D printed calibration piece can complete the pose positioning of the corresponding joint. However, in actual tests, it was found that since 3D printed parts may undergo a certain degree of bending or deformation during the loading process, when only a single calibration piece is used, the repeatability and reliability of positioning are insufficient. Therefore, additional constraints were introduced at the sole position, and an appropriate over-constrained design was implemented for the system.
4. 3D Printed Part Removal#
Since the 3D printed calibration part at this position is prone to breakage during the disassembly process, and may get stuck in the slot after breaking, users need to be extra cautious when knocking out the calibration part. If the calibration part accidentally breaks and gets stuck inside, a hot air gun can be used to heat the local area to soften the 3D printing material, and then it can be removed with the help of tools.
If users have better mechanical or structural solutions regarding the rotational degree-of-freedom constraints and calibration of the hip joint or other joints, we welcome you to provide us with relevant suggestions so that we can further optimize the calibration design in subsequent versions.