Content#
Document Version: V1.1.1
Effective Date:March 16, 2026
Target Audience: Personnel involved in the assembly, commissioning, and algorithm deployment of the ROBOTO ORIGIN
Pre-reading: Before operation, please ensure that you have read and signed the <RoboParty ROBOTO ORIGIN Prototype Product Disclaimer and Safety Notice>.
Reference Resources: For detailed key mappings and code explanations, please refer to the official documentation website and the official GitHub repository.
Core Warnings#
High Dynamic Risk: The robot has an extremely high risk of instability and toppling during gait debugging. Any suspension zeroing or gait inference test, must be conducted in a controlled area equipped with a load-bearing safety hanger (fall protection).
Physical Emergency Stop Takes Precedence: In case of any uncontrollable joint jitter, gait deviation, or structural interference, please immediately press the "X" button on the remote control handle to trigger software disablement; if the software malfunctions, please immediately press the physical emergency stop switch to cut off the main power supply.
Pre-power-on physical environment and hardware pre-check (must be done before power-on)#
Before powering the main control and drive system, the operator must complete the following verifications:
1.1 Power Supply and Battery Verification#
- Voltage Threshold Check: Check the current voltage of the battery pack. When the battery voltage is below 50V, please charge it immediately. It is strictly prohibited to operate in an undervoltage state; otherwise, undervoltage protection will be triggered, causing abnormal behavior or sudden power failure and falling during the robot's operation.
1.2 Mechanical Structure Verification#
- Key fastener inspection: Focus on checking the fastening status of the ankle link . If the ankle link is loose or fails to reach the specified torque, it will directly lead to abnormal ankle force exertion, and the robot will be unable to stand normally during the inference phase and may damage structural components.
1.3 Communication Link Verification#
- Handle Status Check: Check the remote control handle, press the home button to pair and connect the handle with the receiver, and ensure that the handle mode is in "Xinput" mode at this time, so as to ensure normal communication between the handle and the robot.
Status Enable and Zero Position Initialization (High-Risk Operation Phase)#
This stage involves the instantaneous output of motor torque and position closed-loop control, and must be carried out with the robot suspended using a safety hanger .
2.1 Status Enable#
Initial state confirmation: After the robot's main power is turned on, the status indicator lights of all motors on the body should default to be red (disabled state).
Motor Enable: Press the "X" button on the remote control, and the system will issue an enable command. At this time, visually check whether the indicator lights of all motors on the body have turned green .
Disable Test: Before the formal operation, it is recommended to press the "X" key again to test whether the disable function is normal (the indicator light switches back to red), and re-enable it after confirmation.
2.2 Zero Deviation Verification (Loss Prevention Protection)#
Pre-adjustment of posture: After the motor is enabled, the motor can be manually adjusted to make the robot's posture similar to that at joint_default_angle, preventing sudden movements and damage to the motor and structural components.
Terminal Verification: After the adjustment is completed, you can use the following commands to check the deviation between the current joint angle and the zero point. Connect to the main controller using a network cable and create two new terminals on the main controller.
First, enter the following command in the first terminal to subscribe to the joint pose topic:
source /opt/ros/humble/setup.bash
ros2 topic echo /joint_statesThen enter the following in another terminal:
source /opt/ros/humble/setup.bash
ros2 service call /refresh_joints std_srvs/srv/Trigger
ros2 service call /read_joints std_srvs/srv/TriggerCalibration Judgment: Wait a moment. The first terminal will print out the deviation between the current joint angle and the zero point. If the deviations are all around joint_default_angle, the reset operation can be performed. If the deviations are large, please check whether the motor has been zeroed or whether the zeroing operation is correct. Pay special attention to the calibration direction when using the limit block to calibrate the waist yaw joint, which should be that the upper body rotates counterclockwise to the limit block while the lower body remains stationary.
2.3 Specification for Floating Reset Operation#
Precondition for zero calibration: Before performing the Reset action, it must be confirmed that all motors have completed absolute zero calibration. Do not perform the reset operation before the motors are zero calibrated! It is recommended to perform the reset operation using the hanger in the air.
Pose Matching: When pressing the "A" button on the controller to perform Reset (return the motor to the preset zero position), the operator needs to manually intervene with the robot's limbs, ensuring that the robot's current physical pose is as close as possible to the set Reset zero position pose.
Position mutation warning: If the physical attitude deviates too much from the zero position, a large step response (motion mutation) will occur instantaneously during Reset, which can easily damage the motor reducer and structural components.
Model Inference and Dynamic Operation (Physical Machine Deployment Phase)#
After confirming that the Reset is completed, the joint state is stable, and there is no abnormal current noise, enter the inference state according to the following specifications:
3.1 Landing and Pose Preparation#
- Smooth Landing: After Reset is completed, lower the robot smoothly from the safety hanger. The operator shall observe and confirm that both feet are fully on the ground and the center of gravity is evenly distributed.
3.2 Joystick Dead Zone Elimination#
- Instruction Clearance: Before pressing "B" for inference, be sure to manually move the left and right joysticks through their full range of motion and press the "LT" and "RT" buttons several times. This operation is used to eliminate the dead zone or drift of the hardware joysticks, preventing residual instructions from causing the robot to unexpectedly drift or sprint at the moment inference starts.
3.3 Node Status Monitoring and Inference Initiation#
Background Status Confirmation: The operator must use the
screen -r inference_nodecommand on the host computer terminal to check the running status of the inference node. Only after confirming that there are no Error reports can the next step be taken.Start inference: Press the "B" button on the remote control to officially enter the model inference state. At this time, the supervisor needs to closely monitor the robot's gait, hold the hanger control rope, or be ready to press the "X" button at any time.
Anomaly troubleshooting and emergency response#
During the full lifecycle of operation, in case of emergencies, please handle them according to the following logic:
One-key Disable (Emergency Stop): If any abnormal behavior (such as high-frequency oscillation, joint overspeed, instability and toppling) occurs during the robot's reasoning process, please immediately press the "X" key to cut off the motor enable.
Abnormal disconnection troubleshooting: If the robot experiences a non-human-triggered "sudden incapacitation" (collapsing to the ground) during inference, please maintain the scene as it is and immediately use
screen -r inference_nodeto enter the terminal and check the error message. Common causes include:- The algorithm layer has triggered the set safety limits (such as joint overrun, speed overrun).
- The hardware layer has triggered overload, overheat, or under-voltage protection.
Log Retention: Before disconnecting the main power supply, it is recommended to export the Error log from the terminal first, so that the R&D team can locate the root cause of the problem.
Supplementary Instructions for Operation#
For details on the functions and operations of each button, please refer to the RPO deployment README.